Stability of Built-up Cold-Formed Steel Box Columns Made from Hat-Shaped Sections with and without Concrete Infill under Axial Loading: Experimental and Numerical Investigation
CMES - Computer Modeling in Engineering and Sciences, cilt.149, sa.2, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 149 Sayı: 2
- Basım Tarihi: 2026
- Doi Numarası: 10.32604/cmes.2026.090637
- Dergi Adı: CMES - Computer Modeling in Engineering and Sciences
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Aerospace Database, Compendex, INSPEC, zbMATH, Materials Science & Engineering Collection (ProQuest), Technology Collection (ProQuest)
- Anahtar Kelimeler: ABAQUS, axial compression, built-up sections, Cold-formed steel, concrete-filled columns, distortional buckling, finite element analysis, local buckling, Omega profiles
- İstanbul Gelişim Üniversitesi Adresli: Evet
Özet
Concrete-filled cold-formed steel (CFS) columns combine a high load-carrying capacity with a low self-weight, which makes them an efficient solution for steel construction. This study presents a numerical and experimental investigation of the axial compression behavior of innovative concrete-filled CFS columns. Two cross-sectional configurations, Omega and Super Omega, were investigated. The proposed system consists of two identical profiles placed back-to-back and connected by resistance spot welds to form a built-up box section, in accordance with the principles of Eurocode 3, Part 1–3. The experimental program included tensile tests on steel coupons, compression tests on concrete cubes, and axial compression tests on eight column specimens with different configurations and slenderness levels. These tests were conducted to characterize the material properties and evaluate the column behavior in terms of load-carrying capacity, deformation, and failure modes. In parallel, a nonlinear finite element model was developed using ABAQUS to reproduce the behavior of the tested columns. The model accounts for material nonlinearities, buckling behavior, and steel–concrete interaction. The numerical results were compared with the experimental results in terms of ultimate load, displacement, strain, and failure mode. The comparison showed good agreement between the numerical and experimental results, highlighting the beneficial effect of concrete filling on the load-carrying capacity and overall stability of the investigated Omega and Super Omega columns under axial compression. Compared with the corresponding unfilled columns, concrete filling increased the load-carrying capacity by 107.24% to 115.98% in the tests (110.26% to 111.76% in the finite element models) and significantly reduced the maximum lateral displacement, demonstrating its beneficial effect on the deformation control and overall stability of the investigated columns.