Optimization of heat transfer surface distribution in a double-shell latent heat thermal energy storage system: Comparative analysis of charging characteristics, melting dynamics, and operating conditions


He J., Xu G., Abu-Zinadah H., Althobaiti M. A. O., Mengash H. A., Zhang C., ...Daha Fazla

International Communications in Heat and Mass Transfer, cilt.181, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 181
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1016/j.icheatmasstransfer.2026.113099
  • Dergi Adı: International Communications in Heat and Mass Transfer
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Compendex, INSPEC, Academic Search Ultimate (EBSCO), Engineering Source (EBSCO)
  • Anahtar Kelimeler: Charging performance, Double-shell storage system, Heat transfer surface distribution, Latent heat thermal energy storage, Melting characteristics, Phase change material
  • İstanbul Gelişim Üniversitesi Adresli: Evet

Özet

Latent heat thermal energy storage (LHTES) systems employing phase change materials (PCMs) have emerged as a key technology for offering high energy storage density and nearly isothermal operation during phase transition. Nonetheless, the inherently poor thermal conductivity of most PCMs significantly limits the overall thermal performance in these systems. The current study proposes a double-shell LHTES configuration. This design integrates the storage enclosure, heat transfer fluid (HTF) channels, and supporting structures into a unified aluminum body, reducing thermal resistance and increasing the effective heat transfer area. The internal shell creates multiple PCM compartments and provides greater flexibility for thermal management applications. Three configurations, distinguished by the inner-shell diameter and the resulting distribution of HTF tubes within the PCM domain, are systematically investigated to identify the optimal geometric arrangement. After selecting the optimum configuration, numerical simulations comprehensively examine the effects of HTF inlet temperature and inlet velocity on the storage unit's melting behavior. Among the investigated geometrical configurations, Case B (with the intermediate inner-shell diameter) demonstrates the best overall performance, despite having a slightly lower heat transfer surface area than Case C. Case B achieves complete melting within 14,700 s, while Case A requires 16,500 s, and Case C fails to reach full melting even after 18,000 s. Increasing the HTF inlet temperature from 328.15 K to 343.15 K increased total energy storage by about 60.8%. Raising the HTF inlet velocity from 0.005 m/s to 0.03 m/s increased total energy storage by only ~7.6%, showing a weak sensitivity to velocity.